MCU8650 train 13 version upgrade, MCU can register to the SMC but the problem can not be registered to GK

Publication Date:  2013-07-30 Views:  73 Downloads:  0
Issue Description
An operator MCU8650 train 13 version upgrade, MCU can register to the SMC but not registered to GK, in SMC2.0 maintenance interface, MCU8650 the SMC registration status is displayed in green, GK registration status is gray, which means that can not be registered to GK
Alarm Information
None
Handling Process
1, troubleshoot network can ping each other is through the network properly.
2, this upgraded version of the MCU and SMC2.0 were upgraded after the upgrade, some MCU is normal, there is only one MCU's registration status is abnormal and no exception occurs during the upgrade process, indicating the software version is not a problem
3, verification docking parameters, IP address and port were normal.
4, check the docking password, since the display is not clear.
5, click SMC2.0 maintenance interface in the "System Management" -> "GK" -> "Node List" -> "Node Details", you can view the "Last RRJ reason" is displayed as "accounts or Incorrect password. (error code 0x65) ", which can be judged docking account password is incorrect, the MCU docking with SMC2.0 Reset password, the problem is solved.
Root Cause
1, network failure
2, the software exception
3, the docking parameter error
Suggestions
1, after backtracking, found during the upgrade process, SMC has appeared abnormal upgrade, upgrade, re-engineer deleted record through the MCU to locate the problem, thus resulting passwords do not match.
2, for the problem of GK successfully registered, you can SMC2.0 maintenance interface in the "System Management" -> "GK" -> "Node List" -> "Node Details" view detailed failure information, such positioning gradually narrow the scope of the problem can be

END