Publication Date:  2013-08-26 Views:  57 Downloads:  0
Issue Description
EMS add bir fail,popup NE is exist.
Alarm Information
 NE is exist.
Handling Process
get the log UOA ,especilly the debug log .

in the log of debug ,we found that , HW-SUR-EL-MIB.xml is failed to load .


1. For the bir register to ems ,we found that HW-SUR-EL-MIB.xml is failed to load .
Please check the permission of this file ,and show me the result , if possible ,maybe you can try to replace the file ,which I attach it .make sure the file have all write and read permission .

--------------RegisterModule-------------
SequenceID      = 1
ModuleType     = 4500101
ModuleName  = UniBI
ModuleVer       = UniBI
WorkingMode = 1
WorkStatus      = 1
NEType    = 45001
NEID         = 45001
NEName  = SUR
IPAddr      = 10.26.62.113
HostName        = MPV1CCODREPORT1
ModuleCode    = 0000000000000
BackUpNode    =
AdapterID        = sxpadapter_0
InnerID    =
ExtField    =

Aug 20 10:05:10:906979 [Debug3] ThreadID:3977296752    >>> Succeed in loading alarm info file (AlarmInfo_45001_en.res)!
Aug 20 10:05:10:907395 [Debug3] ThreadID:3977296752    >>> Succeed in loading alarm keyword file (AlarmKeyWords_45001_en.res)!
Aug 20 10:05:10:907600 [Debug1] ThreadID:3977296752    >>> Fail to read file (/home/uoa/setup/data/mib/HW-SUR-EL-MIB.xml)
Aug 20 10:05:10:907614 [Debug1] ThreadID:3977296752    >>> Failed to parser mib file(/home/uoa/setup/data/mib/HW-SUR-EL-MIB.xml)!
Aug 20 10:05:10:907751 [Debug1] ThreadID:3977296752    >>> Fail to load the mib object to context(0054500101001)!
Aug 20 10:05:10:907804 [Debug3] ThreadID:3977296752    >>> Succeed in unloading alarm resource file!
Aug 20 10:05:10:907875 [Debug3] ThreadID:3977296752    >>> Need not to unload the mapfiles, contextname is 0054500101001!
Aug 20 10:05:10:908219 [Debug1] ThreadID:3977296752    >>> begin to call onRegisterModule
Aug 20 10:05:10:912969 [Debug1] ThreadID:3977296752    >>> Succeed in call onRegisterModule : o


copy the file to the folder is a step of install bir ,so we ask customer to copy it again ,and give the full permission of read write .than problem resolved .
Root Cause
for the alarm ,we check the ne.dat first to check if there is any infomation of BIR ,result is no .

that means ,the popup is wrong information .

bir will register to UOA first ,so we should get the log of uoa.
Suggestions
in linux ,be carefull of the permission .

END