MCU9620 can't call MC850

Publication Date:  2013-09-09 Views:  80 Downloads:  0
Issue Description
MC850  can call to conference, but it can't receive a request  from MCU9620 to join conference.
the MC850and MCU are all  registered on SIP server

Alarm Information
no
Handling Process
change the SIP setting of MCU  from TCP to UDP
Root Cause
we can see the MCU call MC850 via TCP,but when MC850call MCU it use UDP 
Suggestions
none