iSCSI connection can not reconnect after storage reboot

Publication Date:  2013-09-24 Views:  133 Downloads:  0
Issue Description
The customer build the iSCSI connection and enable chart certificate:

When you input the password length which is longer than 17.  After reboot the system , you found the iSCSI connection is disconnected.  If you delete the connection and rebuild it. The connection is fine.
Alarm Information
No Alarm
Handling Process
1) Please make sure the charp password from the client is from 12 to 16. 
2) Please make sure the charp password on ISM is the same with the client.

Root Cause

The password of charp should be from12 to 16 characters.  And should be the same with the client. If the customer  input more than 17 characters in our system, there is no alert. But the customer would  think he is right.

Suggestions

Add alert when the customer input the password which is longer than 16 characters.

END