Connecting 2 SANs to CX311

Publication Date:  2013-12-09 Views:  182 Downloads:  0
Issue Description
After connecting 2 SANs to the CX311 all the volumes disappeared 
Alarm Information
Alarm Msg: [Wed Aug 21 03:50:38.467 UTC 2013][A][1005.0103][Potential misconfiguration: TF ports of the same port group discovering multiple fabric names.]
Handling Process
customer must use the following topology 


Root Cause
Customer needs to connect 2 FC SANs ( IBM and NetApp) 
Each FC is connected to 2 FC Switchs 
as a result each CX311 is connected to more than 1 FC switch 

CX311 can't be connected except to a single FC switch while working in transparent mode 
Suggestions
None