BMP add 2980 fail

Publication Date:  2013-12-28 Views:  124 Downloads:  0
Issue Description
after  install a new uc2.0 system ,when add u2980 to bmp ,it prompt add fail .
Alarm Information
possible cause: parameter error
Handling Process

we delete the IFC template:
Use command
LST SIFCTPL:;
To find out 2 Template named “IFCTEMPLATE” and “PSITEMPLATE”,and find out the shared ifc id

Use command below to delete IFC,=1 should  be change to the real one that you query .
RMV SIFCINF: SIFCTPLID=1;  
RMV SIFCINF: SIFCTPLID=2;  

Use command below to delete IFC template ,=1 should  be change to the real one that you query
RMV SIFCTPL: SIFCTPLID=1;
RMV SIFCTPL: SIFCTPLID=2;


than add again .
OK I removed all IFC data and now I could add U2980:
Root Cause
because prompt parameter error ,first of all ,check the parameter in bmp,but all the parameter looks like all ok .

after customer ,what was the uap used for before ,customer said ,there was used for another uc2.0 system .

so ,maybe problme is that the parameter of uap is for another uc system .
Suggestions
before add u2980 ,make sure that ,the uap is not used for other system before .

END