Spectrum function of esight can not be used after upgrading from SPC100 to SPC200

Publication Date:  2014-01-04 Views:  15 Downloads:  0
Issue Description
version: V2R3C01SPC200
networking: esight directly connect to AC
Symptom: Spectrum function of esight can not be used after upgrading from SPC100 to SPC200, there is no value in spectrum oicture.
Alarm Information
NULL
Handling Process
Add ip address of AC to esight , then the spectrum function become normal.
Root Cause
Considering of safety, the devices which is managed by esight are prevent to send packets to esight by adding filtering function.
We tried to capture packets on esight, we found that the ip address of spectrum packets(UDP port is 32181) is 192.168.255.2, it is the ip address of AC, but this ip address is not added to esight, and it lead to esight filter the packets of spectrum packets from AC and spectrum function of esight can not be used.
Suggestions
Considering of safety, the devices which is managed by esight are prevent to send packets to esight by adding filtering function.
So, we should add ip address of AC, in order to use the spectrum function of esight.

END