Alarm issues related to non-Huawei certified transceiver

Publication Date:  2014-03-19 Views:  61 Downloads:  0
Issue Description
When display trapbuffer, there is warning about non-Huawei certified transceiver
Alarm Information
#Oct 12 2013 02:35:40 S9306 BASETRAP/1/ENTITYINVALID: OID 1.3.6.1.4.1.2011.5.25.129.2.1.9 Physical entity failed. (EntityPhysicalIndex=67747854, BaseTrapSeverity=6, BaseTrapProbableCause=136192, BaseTrapEventType=5, EntPhysicalContainedIn=67633161, EntPhysicalName="XGigabitEthernet2/0/0", RelativeResource="", ReasonDescription="It has been observed that a transceiver has been installed that is not certified by Huawei Ethernet Switch. Huawei cannot ensure that it is completely adaptive and will not cause any adverse effects.If it is continued to be used, Huawei is not obligated to provide support to remedy defects or faults arising out of or resulting from installing and using of the non-certified transceiver.")
 
Handling Process
If the customer don't want to check this kind of alarm, this comand can be used:

[Latin]transceiver phony-alarm-disable
Root Cause
This alarm means the transceiver is non-Huawei certified
Suggestions
None

END