u1910 call out fail

Publication Date:  2014-03-19 Views:  79 Downloads:  0
Issue Description
U1900 send setup to the carrier though pra trunk .but receive dissconnect,reason is ”unspecified”. 
Alarm Information
unspecified
Handling Process
execute config pra huawei on .on 1910 ,call out ,success .
Root Cause
as we can send signlaing and got reply the trunk seems ok ,
from the signlaing the number type of peer side is SDN/telephony numbering plan ,but we are unknow .
so we need to modify the number type .
for pra trunk ,r&d create a command for it :config pra huawei on .
Suggestions
some time the trunk is ok ,but call fail can check if the peer side need a different numbet type ,we can always find it in the signaling .