U1930 for the same E1 different time slot use for calling issue

Publication Date:  2014-09-23 Views:  85 Downloads:  0
Issue Description
Indonesia site, custom use U1930, pra trunk. custom question: he wants to specify ports for incoming circuits ranging from ports 1-7 and ports 10-20 on the outgoing circuit PRA Trunk. 
Solution
   Here is an example to control the outgoing call ,
   For example ,we want phone call to PSTN go through time slot 10—20, you can configure like this :

the first method:
Add office number(you already done ,ignore this step) :
config add office selectcode no 0 repeatroute no
config add office no 0 officeselectcode 0
config add predeal index 1 changetype delete changepos 0 changelen 1   --------config number change ,can ignore                                                                                                                               
config add prefix dn 9 callcategory basic callattribute local cldpredeal yes cldindex 1 officeselectcode 0 clipredeal no uselongcli yes  ----config prefix ,can ignore
config modify cvp type dtu tkcincard 1 direction incoming-------------  so 1 time slot can only receive incoming call.
//(bound the DTU with office number ,here DTU in slot 4 ,in U1930 we use CVS board ,so pls bond CVS with office number, this step you should already finish in LMT ,so no need configure)
config modify cvp type dtu tkcincard 10 direction outgoing-------------so 10 time slot can only send outgoing call.
also custom need to tell telecom company, only send call to 1-7 time slot.

the second method:
config add predeal index 1 changetype delete changepos 0 changelen 1   --------config number change ,can ignore                                                                                                                               
config add prefix dn 9 callcategory basic callattribute local cldpredeal yes cldindex 1 officeselectcode 0 clipredeal no uselongcli yes  ----config prefix ,can ignore
config add office selectcode no 99 repeatroute no //config an unrelated office selectcode
config add office no 99 officeselectcode 99 //config an unrelated office no
config modify cvp type dtu tkcincard 1-7 officeno 99 //bind the non 1-10 time slot to unrelated office no
also custom need to tell telecom company, only send call to 1-7 time slot.



END