eSight Unable to Add S5500T using SMI

Publication Date:  2014-12-29 Views:  67 Downloads:  1
Issue Description
eSight V300R002C00SPC300 Unable to Add S5500T V200R002C00 using SMI-S
Alarm Information
Failed to obtain device information when adding using SMI-S
Handling Process
1. Check connectivity between eSight and S5500T. Ping test passed.
2. Check version compatibility between eSight and S5500T. Found to be compatible
3. Check SMI-S service on S5500T. SMI-S service activated on S5500T
Solution
Use REST Protocol instead of SMI-S as a workaround.