An RH2285 Is Powered On by Pressing the Power Button After Connected to AC Power Supplies

Publication Date:  2015-06-18 Views:  71 Downloads:  0
Issue Description
After an RH2285 is connected to alternating current (AC) power supplies, you must press the power button on the front panel to start the RH2285 if the RH2285 fails to start within a minute.

Handling Process
1.  After startup, hold down Delete to open the BIOS, and click Advanced.



2.  Select IPMI 2.0 Configuration, and press Enter.



3.  Select Restore on AC Power Loss, and press Enter. Select Power on from the displayed three options, and press F10 to save the settings and exit.



4.  Remove and reinstall AC power cables. Then the problem is resolved.
Root Cause
Restore on AC Power Loss in the basic input/output system (BIOS) is set to power off.

The following describes three setting items for Restore on AC Power Loss:

END