The License Key for Cascading E6000 NX120 Switch Modules Fails to Be Activated

Publication Date:  2015-06-25 Views:  110 Downloads:  0
Issue Description
Hardware configuration:
Four E6000 blades and eight E6000 NX120s

Symptom:

A customer applies for activating the license key for cascading NX120s at http://www.brocadechina.com/. When onsite engineers activate the license key, errors occur, as shown in the red box in Figure 1.

Figure 1 Errors against activating the license key

Handling Process
BROCADE updates the transaction key database information.

Root Cause
Check that the values of ID Type and Transaction Key for the license key are correct. According to the feedback from BROCADE, the transaction key database of BROCADE is abnormal.

END