All Boards Are Displayed In Grey on the U2980 Simulated

Publication Date:  2015-07-01 Views:  55 Downloads:  0
Issue Description
On the CDE client, all boards are displayed in grey on the U2980 simulated panel.
Handling Process
1. Log in to the CDE client. For details, seeCommissioning Guide > Appendix B:FAQs > Logging In to the OMU Client .
2. Run the LST DEVNO command on the UAP NE and view the value of Device No.
3. Verify that the device ID specified by the DIP switches on the subrack is the same as the value of Device No.
If the device ID specified by the DIP switches on the subrack is different from the value of Device No, the CDE client fails to connect to the U2980.
If the device IDs are different, run the SET DEVNO to change the value of Device No. About 5 minutes later, the board status is displayed correctly on the CDE client.
Root Cause
The U2980 device ID configured on the CDE client is different from the device ID specified by the DIP switches on the subrack. 