OceanStor N8500 V2R1 - The DMP path of cluster NAS engine node (Node_Name) accessing storage unit is faulty. Alarm ID: - 0x3021F0023

Publication Date:  2016-01-12 Views:  67 Downloads:  0
Issue Description

Device: OceanStor N8500 V200R001C00

The DMP path of cluster NAS engine node (Node_Name) accessing storage unit is faulty.

Alarm Information





Impact on the system: - These reduce the reliability of access to back-end storage unit. If the full paths are failure, it will interrupt the business.

Handling Process

Check the FC connection between NAS/FC Switch/Storage Unit. Make sure the connection and zone configuration is configured correctly.

Root Cause

Collect log file from ISM. Link between N8500 engine and OceanStor S5600T is down. Root caused was, OceanStor S5600T is rebooted.



Solution

Then, run the following command:

Login with master account and run command: storage disk list paths:-

According to the output, all the paths are enabled. No disabled paths. Alarm can clear manually.

Suggestions

Login ISM and check which Clustered NAS engine node name accessing storage unit is faulty.



Mainly check below parameter:-

1) Optical fiber is removed or damaged.

2) The controller of storage unit is abnormal.

3) The management network port or the management module fails.

END