whole SAS disks in S5500TV2R2C20 occurred firmware need upgrade notification

Publication Date:  2016-06-01 Views:  169 Downloads:  0
Issue Description

Device info:

SUMMARY-----------------------------
    Product Model: OceanStor S5500T
    Product vesion: V200R002C20
    System Name: S5500T_01
    Product Serial Number: 210235853510EB000001
    System Location: Pacnet SGCS2

Hard disk info:

    Disk ID: 595
    Disk Domain ID: 0
    Disk Frame and Slot ID: DAE004.14
    Disk Type: SAS
    Disk Health Status: NORMAL
    Disk Running Status: ONLINE
    Raw capacity: 837(GB)
    Device Block Number: 1756993072
    Disk Multipathing: ["A","B"]
    Disk Sector Size: 512
    Disk Impending Fault Flag: FALSE
    Disk Slowing Flag: FALSE
    Disk SN: W8HDA67C
    Disk Temperature: 30
    Disk Power-On Time: 97(H)
    Disk Speed: 10000(RPM)
    Disk Physical Size: 3
    Disk Port Address: 50C45BADE5CCA00E
    Disk Vendor: Hitachi
    Disk Model: HUC109090CSS600
    Disk Firmware: A740

Information from Event:

2016-01-29 21:32:18    0x100f000a004d    Infor    None    The firmware version (A740) of the disk (Disk Enclosure DAE004, slot 23, serial number W8HDHG8G) needs to be upgraded. The use of the disk may be affected.
Step 1 Upgrade the firmware version of the disk.

2016-01-29 21:32:18    0x100f000a004d    Infor    None    The firmware version (A740) of the disk (Disk Enclosure DAE004, slot 22, serial number W8HDKGYG) needs to be upgraded. The use of the disk may be affected.
Step 1 Upgrade the firmware version of the disk.

2016-01-29 21:32:18    0x100f000a004d    Infor    None    The firmware version (A740) of the disk (Disk Enclosure DAE004, slot 21, serial number W8HDJMXG) needs to be upgraded. The use of the disk may be affected.
Step 1 Upgrade the firmware version of the disk.

2016-01-29 21:32:18    0x100f000a004d    Infor    None    The firmware version (A740) of the disk (Disk Enclosure DAE004, slot 20, serial number W8HBL4VG) needs to be upgraded. The use of the disk may be affected.
Step 1 Upgrade the firmware version of the disk.

2016-01-29 21:32:18    0x100f000a004d    Infor    None    The firmware version (A740) of the disk (Disk Enclosure DAE004, slot 19, serial number W8HBLNXG) needs to be upgraded. The use of the disk may be affected.
Step 1 Upgrade the firmware version of the disk.

2016-01-29 21:32:18    0x100f000a004d    Infor    None    The firmware version (A740) of the disk (Disk Enclosure DAE004, slot 18, serial number W8HBWLJG) needs to be upgraded. The use of the disk may be affected.
Step 1 Upgrade the firmware version of the disk.

2016-01-29 21:32:18    0x100f000a004d    Infor    None    The firmware version (A740) of the disk (Disk Enclosure DAE004, slot 17, serial number W8HDL7HG) needs to be upgraded. The use of the disk may be affected.
Step 1 Upgrade the firmware version of the disk.

Alarm Information

Information from Event:

2016-01-29 21:32:18    0x100f000a004d    Infor    None    The firmware version (A740) of the disk (Disk Enclosure DAE004, slot 23, serial number W8HDHG8G) needs to be upgraded. The use of the disk may be affected.
Step 1 Upgrade the firmware version of the disk.

Root Cause
The storage version judge trigger fault, this firmware don't need to occur notification.