Oceanstor 5500V3 V300R003C00SPC100-Failed to add the iscsi link when build the remote replication

Publication Date:  2016-06-22 Views:  109 Downloads:  0
Issue Description

Customer reported that they failed to add replication iSCSI link. The issue is as following image:

    
Alarm Information
NA
Handling Process

 Analysis on Storage

    On the storage, there is log show that the replication link is out of specification.

The replication link max number in current version is 8. The FC and the iSCSI share the quota. If the FC links occupy the all 8 quota, the later configured iSCSI link can not apply related resource and cause the failure of adding remote link.

Root Cause
The remote replication link quota is occupied by FC, make the iSCSI link invalid and the failure of adding remote iSCSI link.
Solution

The replication link quota specification is as following:

http://support.huawei.com/enterprise/docinforeader.action?contentId=DOC1000084218&idAbsPath=7919749|7941815|21430818|21462748|21122033

we recommend configure the FC switch zone to avoid this kind of issues.

Suggestions
NA