Succeed finish the culster of VCN3000(3 pcs), it's failed to live feed the cameras which aren't resgisterd on the VCN3000(Float Gateway)

Publication Date:  2016-07-05 Views:  84 Downloads:  0
Issue Description

1. Create the culster with 3 pcs of VCN3000, the IP address are: 10.93.0.122, 10.93.0.123, 10.93.0.124.

2. Configure the VCN3000(10.93.0.122) as the "Float Gateway", and the VCN3000(10.93.0.123, 10.93.0.124) as the cluster server.

3. Login the IVS Client and check the status of the cameras: all the cameras are online. 

4. Live feed:

  (1) It's successful to live feed the cameras which are registered on the Float Gateway(10.93.0.122).

  (2) It's failed to live feed the cameras which aren't registerd on the Float Gateway. The error is "Operation Failure. The response timed out. Error code:999115450".

5. The version of the VCN3000 is: V100R002C10SPC100.


Handling Process

1.Use SSH to login the VCN3000s and shutdown the firewall of VCN3000: 10.93.0.123, 10.93.0.124.

2.After shutdown the firewall, then it's ok to live feed all the cameras with IVS Client.

Root Cause
1.After the cluster configuration, the cluster server's firewall are working, that's why fail to live feed the cameras.
Solution
1. When finish the cluster of the VCN3000s, shutdown the firewall of the all the VCN3000.

END