Issue Description

A customer found there are many alarm “The log format is incorrect” in LogCenter


 
And the software version of LogCenter is :


 

Solution
 

Step 1: Checked the detail of such alarm, and found that it is “dataflow logs”.

Step2:  Login USG6500, and found that there are some audit logs.

Step3: Login USG using audit account, and found there is  audit-policy which will generate audit logs.

The detail audit configuration:

 

Step4:  For current software version of V100R001C20SPC101, it is not support audit logs.  After disable audit policy, and clear the current alarm in LogCenter, there is no more such alarm.

Step5: In future, R&D department will release a new version of LogCenter to support all the audit logs sent by USG6600.

END