OceanStor S5500T After Expansion Produce Power Module Alarm

Publication Date:  2016-11-23 Views:  115 Downloads:  0
Issue Description

After storage expansion, there is Major power module alarm triggered in storage for disk enclosure DAE999.



Alarm Information


2016-09-16 13:49:11    0xf00170014   Major    None    No power is input to the power module (disk enclosure DAE999, power module 3).

2016-09-16 13:49:11    0xf0170003    Major   None    The power module (Disk Enclosure DAE999, power module 2) is faulty with error code (--).



Handling Process

After checking running data, there is no DAE999 Disk Enclosure found.  All other PSU's running status is Online.


Below shows running status for all other power supplier :-


Power Info--------------------------------
        Enclosure ID: ENG0
        Power ID: ENG0.POWER.A0
        Location: ENG0.POWER.A0
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: EMR 
        Model: HSP650-S12A
        SN: 210213G00821480200AB
        Version: 03
        Produce Date: 2014-08-28

        Enclosure ID: ENG0
        Power ID: ENG0.POWER.A1
       Location: ENG0.POWER.A1
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: EMR 
        Model: HSP650-S12A
        SN: 210213G008214802009F
        Version: 03
        Produce Date: 2014-08-28

        Enclosure ID: DAE000
        Power ID: DAE000.POWER.0
        Location: DAE000.POWER.0
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: VAPEL
        Model: HSP480-S12A
        SN: 210213G0068NE9001717
        Version: 12
        Produce Date: 2014-10-24

        Enclosure ID: DAE000
        Power ID: DAE000.POWER.1
        Location: DAE000.POWER.1
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: VAPEL
        Model: HSP480-S12A
        SN: 210213G0068NE9002236
        Version: 12
        Produce Date: 2014-10-22

        Enclosure ID: DAE000
        Power ID: DAE000.POWER.2
        Location: DAE000.POWER.2
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: VAPEL
        Model: HSP480-S12A
        SN: 210213G0068NE9001871
        Version: 12
        Produce Date: 2014-10-24

        Enclosure ID: DAE000
        Power ID: DAE000.POWER.3
        Location: DAE000.POWER.3
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: VAPEL
        Model: HSP480-S12A
        SN: 210213G0068NE9001854
        Version: 12
        Produce Date: 2014-10-23

        Enclosure ID: DAE001
        Power ID: DAE001.POWER.0
        Location: DAE001.POWER.0
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: VAPEL
        Model: HSP480-S12A
        SN: 210213G0068NEB002077
        Version: 12
        Produce Date: 2014-11-22

        Enclosure ID: DAE001
        Power ID: DAE001.POWER.1
        Location: DAE001.POWER.1
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: VAPEL
        Model: HSP480-S12A
        SN: 210213G0068NEB002768
        Version: 12
        Produce Date: 2014-11-21

        Enclosure ID: DAE001
        Power ID: DAE001.POWER.2
        Location: DAE001.POWER.2
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: VAPEL
        Model: HSP480-S12A
        SN: 210213G0068NEB002457
        Version: 12
        Produce Date: 2014-11-21

        Enclosure ID: DAE001
        Power ID: DAE001.POWER.3
        Location: DAE001.POWER.3
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: VAPEL
        Model: HSP480-S12A
        SN: 210213G0068NEB002061
        Version: 12
        Produce Date: 2014-11-23

        Enclosure ID: DAE002
        Power ID: DAE002.POWER.0
        Location: DAE002.POWER.0
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: EMR 
        Model: HSP480-S12A
        SN: 210213G00621G3000605
        Version: 02
        Produce Date: 2016-03-25

        Enclosure ID: DAE002
        Power ID: DAE002.POWER.1
        Location: DAE002.POWER.1
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: EMR 
        Model: HSP480-S12A
        SN: 210213G00621G3000557
        Version: 02
        Produce Date: 2016-03-25

        Enclosure ID: DAE002
        Power ID: DAE002.POWER.2
        Location: DAE002.POWER.2
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: EMR 
        Model: HSP480-S12A
        SN: 210213G00621G3000891
        Version: 02
        Produce Date: 2016-03-25

        Enclosure ID: DAE002
        Power ID: DAE002.POWER.3
        Location: DAE002.POWER.3
        Health Status: Normal
        Running Status: Online
        Type: AC(No Battery)
        Vendor: EMR 
        Model: HSP480-S12A
        SN: 210213G00621G3001157
        Version: 02
        Produce Date: 2016-03-25

Root Cause
1) During the DAE002 insert the system first time, the Controller B connect to the disk frame first. Hence the DAE labeled as DAE 999.
2) In a minute, the Controller A connect the disk frame ,so the DAE number changed to DAE 002
3) The history alarm about the DAE999 remain in the storage but the disk enclosure as been renamed to DAE002. Hence the alarm cannot recovered automatically.
Solution
Manually clear the alarm.
Suggestions

After deep analyzing there is no issue on the power supply in DAE002 and also in other disk enclosure. Suggest first to check the logs to find out the root cause. If the root cause is not related to hardware level we can clear the alarm manually.


END