TP3106 shows alarm dont detect recording system.

Publication Date:  2017-02-14 Views:  635 Downloads:  0
Issue Description

TP3106 shows alarm for disconnection with recording server, but recording server in not included it.

TP3106 version: V100R001C02.


Alarm Information

Recording server not detected it.



Handling Process
 Disable Recording server. 
Root Cause
Due Recording server is not included but TP enable this function. 
Solution

Access by command line to TP host and input command to disable Recording server:


     cm setproductType EnableRecplay 0


Then restart TP host: keyctrl reboot yes