Publication Date:  2017-06-30 Views:  110 Downloads:  0
Issue Description
000
From: Jorge Gomes [mailto:jgomes@aiuken.com] Sent: Monday, June 5, 2017 3:20 PMTo: pmail_Eusupport <eusupport@huawei.com>Subject: Build in Portal in FAT AP4030DN SN 21500826432SF9900040 Hi, we are trying to configure two SSID with 2 different vlans.We are using Build in Portal with local users but We only are able to run oneof them, There is a way to configure two SSID with 2 different vlansand using two differente Build in Portal ? Thank you, Regards.
Handling Process

 

The customer asked how can he to configure Portal built in and how to configure multiple SSID
Root Cause

Configuration request.

Solution

Configuration
example for first ssid&vlan:

ssid-profile
name wlan-ssid
 
ssid wlan-net

vap-profile
name wlan-vap
 
service-vlan vlan-id 101
 
ssid-profile wlan-ssid
 
security-profile wlan-security
 
authentication-profile p1

Configuration
example for the second ssid&vlan:

ssid-profile
name wlan-ssid2
 
ssid wlan-net2

vap-profile
name wlan-vap2
 
service-vlan vlan-id 102
 
ssid-profile wlan-ssid2
 
security-profile wlan-security
 
authentication-profile p1



END