No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Lun Replication between S5300 V3 & S2600 V3

Publication Date:  2017-08-11 Views:  481 Downloads:  0
Issue Description

when try to create LUN replication, found no resources from the remote device

 

Alarm Information

none.

Handling Process

1-checking license features validity of both storage.

2-checking Replication Link status.

3-Make sure both primary and remote LUNs have the same capacity.

4-Make sure that remote LUN is unmapped from any LUN Groups.

Root Cause

1-License replication features is not valid.

2-both primary and remote LUNs is not with the same capacity.

3-the replication Link status is down.

4-the remote LUN is mapped to a LUN Group.

Solution

1-Checking the License features validity of both storages.

Choose Settings > License Management.

2-Checking Replication Link status.

Choose Data Protection > Remote Device.


3-Make sure both primary and remote LUNs have the same capacity.


4-Make sure that remote LUN is unmapped from any LUN Groups.

Choose Provisioning > LUN.
 
 
5-Create LUN replication.

Choose Data Protection > Remote Replication.

Suggestions

none.

END