SIP Trunk Calling ID faulty in eSpace U2980 when the calling from SIP Extension

Publication Date:  2017-08-17 Views:  45 Downloads:  0
Issue Description

When the customer call from SIP Extension 3110 to mobile number, his  Trunk ID 9000000 is shown on mobile, which is good.

But when he call from SIP Extension 3110 to Landline number, my Extension 3110 is shown on landline telephone set


Handling Process

we asked the customer about some information and received his reply:-

1-the version of espace U2980.

 

%%LST VERINFO:;%%

RETCODE = 0  Operation succeeded.

 

The result is as follows

------------------------

 CDE version  ME type  ME version         Module description  Module version   

 

 V100R001C10  CDE      V100R001C10SPC500  SMU                 V100R001C10SPC500

 V100R001C10  CDE      V100R001C10SPC500  DMU                 V100R001C10SPC500

 V100R001C10  CDE      V100R001C10SPC500  SRMU                V100R001C10SPC500

 V100R001C10  CDE      V100R001C10SPC500  IMU                 V100R001C10SPC500

 V100R001C10  CDE      V100R001C10SPC500  AMU                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  CCU                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  CDB                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  BSG                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  IFM                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  MSG                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  MSU_BSI             V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  MSU_IO              V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  MSU_MVP_SSM         V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  MSU_MVP_DATA        V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  CMU                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  CIU                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  MDU                 V100R001C10SPC500

 V100R001C10  UAP      V100R001C10SPC500  STU                 V100R001C10SPC500

2-the full network topology.

U2980 is connected with PSTN through SIP Trunk and provides Call center services through CTI.

3-is it working well before and the issue occur or is that first time to work.

First time configuration

4- is the issue happen after any configuration applied .

No.

----------------------------------------------------------------------------------------------------------------

then we send this the solution to the customer for the two prefixes 9 & 903 

 

 

Query all call prefix processing data.

LST PFXPRO:;

%%LST PFXPRO:;%%

RETCODE = 0  Operation succeeded.

 

LST PFXPRO

----------

Call source code  Local DN set  Call prefix  Call prefix processing name  Nature of callee address indicator  Called number change flag  Method of sending tone  Failure processing flag  Caller number change flag  New DN set  New local DN set  Called number change index  Caller number change index  Reanalysis  Reanalysis items  Tone type  Processing type  Failure cause code           Tone position  Call prefix processing control flag  Common CRBT mode  New call source code  Send answer signal

 

0                 0             222          del222                       all number                          TRUE                       not send tone           FALSE                    FALSE                      0           0                 3                           0                           FALSE       NULL              record 0   0                interconnection not defined  0              normal                               not send          0                     FALSE            

 0                 0             888          del888                       all number                          TRUE                       not send tone           FALSE                    FALSE                      0           0                 3                           0                           FALSE       NULL              record 0   0                interconnection not defined  0              normal                               not send          0                     FALSE            

 0                 0             333          del333                       all number                          TRUE                       not send tone           FALSE                    FALSE                      0           0                 3                           0                           FALSE       NULL              record 0   0                interconnection not defined  0              normal                               not send          0                     FALSE            

(Number of results = 3)

 

---    END

Query call prefix processing data. Set Call source code to 0, Local DN set to 0, and Call prefix to 222.

LST PFXPRO: CSC=0, LP=0, PFX=K'222;

%%LST PFXPRO: CSC=0, LP=0, PFX=K'222;%%

RETCODE = 0  Operation succeeded.

 

LST PFXPRO

----------

                   Call source code  =  0

                       Local DN set  =  0

                        Call prefix  =  222

        Call prefix processing name  =  del222

Nature of callee address indicator  =  all number

          Called number change flag  =  TRUE

             Method of sending tone  =  not send tone

            Failure processing flag  =  FALSE

          Caller number change flag  =  FALSE

                         New DN set  =  0

                   New local DN set  =  0

         Called number change index  =  3

         Caller number change index  =  0

                         Reanalysis  =  FALSE

                   Reanalysis items  =  NULL

                          Tone type  =  record 0

                    Processing type  =  0

                 Failure cause code  =  interconnection not defined

                      Tone position  =  0

Call prefix processing control flag  =  normal

                   Common CRBT mode  =  not send

               New call source code  =  0

                 Send answer signal  =  FALSE

(Number of results = 1)

 

---    END

 

 but it did not solve the issue.

-------------------------------------------------------------------------------------------------

the we Try to change Caller number change index to 12 for prefix 9 as in the information below and feedback us.

 

 

Modify the call prefix processing data. Set Call source code to 0Call prefix to 654Nature of callee address indicator to national number.

MOD PFXPRO: CSC=0, PFX="654", NCAI=NDN;

 but the issue still exist.

-------------------------------------------------------------------------------------------------------------------------------------------------------------------

and the issue is solved as the information below

we solved it by modify the signal type of the office trunk, after we modified this signal type , there is no P-Asserted-ID in the SIP message anymore.

Then the calling number will displayed as the SIP header described , so the calling number on the mobile phone and the landline phone will display as the same.

 

                            The root cause of this issue is that the signaling type is IMS , which will contains the P-Asserted-ID in the SIP message.

                           

                            This is the configuration of this U2980 site, you can see the SIG=IMS of the No.12 OFC which is used for outgoing calls.

                     

 

                            We can modify the signaling type of the No.12 OFC with these commands:

                            We first need to modify and delete the relevant parameters of No.12 OFC, and then re-add an No.12 OFC.

                            In the process of configuring the modification, the No.12 OFC relay service will be affected, so please do this when the traffic is low

                           

                                   MOD RT: R=12, SR1=11;

MOD SIPTG: TG=12, SRT=11;

RMV SRT: SRC=12;

RMV OFC: O=12;

ADD OFC: O=12, ON="SIP Trunk", DOT=CMPX, DOL=SAME, DOA=PSTN, OFCTYPE=COM, SIG=NONBICC/NONSIP, IFCFLAG=NO;

ADD SRT:SRC=12,O=12,SRN="SIP Trunk";

MOD SIPTG: TG=12, SRT=12;

MOD RT: R=12, SR1=12;

 

END