Can not view more than 20 live view panes on the IVS

Publication Date:  2017-08-20 Views:  526 Downloads:  0
Issue Description

Customer is having VCN3010 v100r002c50 and he reported that when he open more than 20 panes live view as per below snapshot 


Handling Process

We send to customer to change the bit rate , resolution  and frame rate in order to open more panes and to check also the connectivity between the IVS and IPC as to make the BW suffiecient and stable 

Log in to the IVS C/S client. > Choose Devices > Local Domain and double-click a camera. The Configuration window is displayed.

Choose Video Settings > Video Encoding Settings.

( NOTE : you can choose to change the whole IPC's configuration by pressing bulk configurtaion in the video settings tab )

After selecting the needed IPC from the left then press bulk configuration , we change the below settings as per below snap shot 

we asked customer to change the resolution to be CIF which is the least resolution , frame rate will be 30 and bit rate to be 512kbps




After that  , restart the IVS client , then open live view tab and try try to open the IPC's from the left by double click on them 

Customer able to open 45 panes as per below snapshot 