service are fully configured .error code 39506

Publication Date:  2017-11-28 Views:  67 Downloads:  0
Issue Description

Customer Node information : OSN8800  ,Software version : V100R009C10SPC300  ,during create ODU2 eletrical cross-connection by trail
TEM28 report error "service are fully configured .error code 39506 "
 

Alarm Information

report error "service are fully configured .error code 39506

Handling Process

1. put ccn by trail report the service are fully configured .error code 39506

2. put ccn within single node still report  service full alarm

3. put unidirectional ccn test ODU2 slot 7 NS4 TO slot 7 ns4  is successful 

4. put unidirectional ccn test ODU2 slot 12 tem28 TO slot 12 tem28 that report service is full

5. check node current ccn configuration , current 1*ODU2 service  +3*ODU0 service are available 

6 .for tem28 there is limitation required totally 20G bandwidth ccn allowed . for customer new ODU2 ccn exceed card limitation
 



Root Cause

for tem28 there is limitation required totally 20G bandwidth ccn allowed . for customer new ODU2 ccn exceed card limitation 

Solution

for tem28 there is limitation required totally 20G bandwidth ccn allowed . for customer new ODU2 ccn exceed card limitation ,deleted odu0 ccn and is able to put second ODU2 CCN

,

Suggestions

tem28 there is limitation required totally 20G bandwidth ccn allowed