FusionInsight HD OMS install failed

Publication Date:  2017-12-13 Views:  647 Downloads:  0
Issue Description

In FusionInsight HD V100R002C70SPC200, when deploy the fusionInsigt Manager report error:

 ws_float_ip_interface=bond0:oms can not be found

Alarm Information

when deploy the fusionInsigt Manager report error:

 ws_float_ip_interface=bond0:oms can not be found

Handling Process

In our design, management port and business port are deployed separately, and make the two NIC port bound.

we design the bound network interface name in LLD design excel, and it is written in install_oms/10.20.63.165.ini (this is the management node IP address)

But In OS,  the interface  name is  "team1" which is different with LLD design, so it is report this error.

 

After we change the interface name in LLD design, then upload it in system, the issue resolved.

Root Cause

The interface name in design configuration script is difference with we set in OS system

Solution

Use the same interface name  between the LLD design and OS

Suggestions

Check the interface name in OS then configure it in LLD design