No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

the OID is not accessible

Publication Date:  2018-01-29 Views:  85 Downloads:  0
Issue Description

The customer would like to monitor pseudowire status (l2vc cirtucits) on a S6720 switch with SNMP. 
According to the documentation, HUAWEI-PWE3-MIB MIB should be used. The OID describing pseudowire ID is 1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.1, object name is hwPWVcID.

Below the error:

snmpwalk -m +HUAWEI-PWE3-MIB -v 2c 10.100.10.205 -cenerGO2004 1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.1

HUAWEI-PWE3-MIB::hwPWVcID = No Such Object available on this agent at this OID

 





 



Solution

For hwPWVcTable, those two objects: hwPwVcID and hwPwVcType are the index of this table and that’s why you can't do” walk” with them.  But, you can see the hwPwVcID and hwPwVcType when you are accessing any other node of this table.

Please see below the results of our test: We are “doing walk” on hwPWVcStatus and in the results below you will see the value for hwPwVcID and  hwPwVcType:

 




The hwPwVcID is 34 and hwPwVcType is 4;





END