Batch ONT can not be auto found in OLT

Publication Date:  2018-02-22 Views:  66 Downloads:  0
Issue Description

Customer is deploying ONT to OLT, they found all ONT can not be auto found in any gpon port of OLT, no matter how to change ONT to which port.

Alarm Information

NO signals(LOS)

Handling Process



1: Check if all GPON ports are enable
laser on.



2: Check if all GPON ports are enable
auto find function.



3: Measure the receiving optical power
in ONT side, there are signal indeed. But ONT is still not be online



4: Check sending optical power of GPON
port is in normal range, and status, Max rate(not 2500000Kbps), undefined
vendor, model of optical module, if plugin wrong module.(e.g. plug in
PX20+)



MINE-OLT-3(config-if-gpon-0/0)#display  port

state 0



 ----------------------------------------------------------------------------

Port Information

----------------------------------------------------------------------------

F/S/P                       

0/0/0

Port

state                  

Online



Last down

cause             

-

 Last up

time                

2017-10-04 09:59:10+08:00

 Last down
time              

-

Port energy-saving flag      No

xPON MAC chipset state       Normal

Signal

detect               

Normal

Available bandwidth(Kbps)    1061492

 Illegal rogue

ONT           

Inexistent

----------------------------------------------------------------------------

Optical Module State

----------------------------------------------------------------------------

Optical Module status        Online

Laser

state                 

Normal

TX

fault                    

Normal

Temperature(C)              

30

TX Bias

current(mA)          24

Supply

Voltage(V)           

3.22

TX

power(dBm)               

3.79

----------------------------------------------------------------------------

Vendor

name                 

HISILICON       

Vendor

rev                  

Unspecified

Vendor

OUI                  

Unspecified

Vendor

PN                   

SSX1T1LTB       

Vendor

SN                   

030SRN6TG1753404

Date

Code                   

16-01-26

Vendor

specific             

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

----------------------------------------------------------------------------

 Optical Module Static Information

----------------------------------------------------------------------------

 Module

type                 

GPON

Module

ub-type             

CLASS B+

Used

type                   

OLT

Encapsulation

Type           SFP

SFF-8472

Compliance          Includes
functionality

described in Rev 9.5

Max

Distance(Km)            

20

 Max

rate(Kbps)              

2500000

 Rate

Identifier             

Unspecified(0x0)

  Wave

length(nm)             

1490

Fiber

type                  

Single Mode

Identifier                  

SFP or SFP interface ID only

Connector                   

SC

Encoding                    

NRZ

Length(9um)(km)             

20.0



Length(50um)(m)             

-

Length(62.5um)(m)           

-

Length(copper)(m)           

-



Length(50um,OM3)(m)          -



BR,max                      

Unspecified



BR,min                      

Unspecified

Diagnostic Monitoring Type   Digital diagnostic monitoring



 Externally Calibrated



                              

Power measurement type: Average Power

\

 

threshold(dBm)              

[-29.2,-8.0]

Rx power alarm



threshold(dBm)              

[-30.0,-7.0]

Tx power warning

threshold(dBm)              

[1.0,5.0]

tx power alarm



threshold(dBm)              

[0.6,5.6]





5: Check the statistics of GMAC in diagnoise,



Display statistics gmac


Explanation to
key words:

Received SN: SN request from ONT to OLT
Ploam sent upstream overhead count: Request from OLT to ONT which need ONT sent OLT

 Display more than two times to compare if all amounts are increased, to prove ONT connect to right gpon port or not.



Root Cause

1: Shut down GPON port on OLT1

2: Display ont autofind in OLT2

3: All ONT connected are reporting register information to OLT2

 

 

Solution

Configure Type B in both OLT1 and OLT2 to make sure the protective mechanism of main fiber when one fiber are broken.

OLT1:

huawei_A(config)#dual-parenting local-node ip-address 192.168.68.1 port 6076 key work_4234
huawei_A(config)#dual-parenting peer-node standby ip-address 192.168.68.8 port 6076 key protect_4234
huawei_A(config)#dual-parenting sync enable
huawei_A(config)#protect-group 1 protect-target gpon-uni-port workmode dual-parenting
huawei_A(protect-group-1)#protect-group member port 0/2/1 role work
huawei_A(protect-group-1)#peer-group-member peer-node standby peer-port 0/2/1
huawei_A(protect-group-1)#uplink-monitor port 0/19/1
huawei_A(protect-group-1)#quit


OLT2:

huawei_B(config)#dual-parenting local-node ip-address 192.168.68.8 port 6076 key protect_4234
huawei_B(config)#dual-parenting peer-node active ip-address 192.168.68.1 port 6076 key work_4234
huawei_B(config)#dual-parenting sync enable
huawei_B(config)#protect-group 1 protect-target gpon-uni-port workmode dual-parenting
huawei_B(protect-group-1)#protect-group member port 0/2/1 role protect
huawei_B(protect-group-1)#peer-group-member peer-node active peer-port 0/2/1
huawei_B(protect-group-1)#protect-group enable
huawei_B(protect-group-1)#uplink-monitor port 0/19/1
huawei_B(protect-group-1)#quit

Suggestions

Before project delivering, we need to know the whole topology first to avoid spending much time to check configuration, going to different site to plug in and out ONT. Maybe after reading topology and LLD, we can make our work efficient.

END