Issue Description

Customer receive folowing message and want to stop receiveig it:

Apr 23 2018 21:18:59 HUAWEI
SRM/3/SFP_EXCEPTION:OID 1.3.6.1.4.1.2011.5.25.129.2.1.9 Optical module
exception, SFP is not certified. (EntityPhysicalIndex=67453134,
BaseTrapSeverity=5, BaseTrapProbableCause=136192, BaseTrapEventType=9,
EntPhysicalContainedIn=67108873

 

When you use a SFP module not certified by Huawei, the module could work fine and you want to stop syslog messages which states the SFP is not certified.

Solution


The transceiver phony-alarm-disable command
disables the alarm function for non-Huawei-certified optical modules.

<HUAWEI> system-view
[HUAWEI] transceiver phony-alarm-disable
Info:Transceiver-phony-alarm disable.

The undo transceiver phony-alarm-disable
command enables the alarm function for non-Huawei-certified optical modules.


By default, the alarm function is enabled for non-Huawei-certified optical
modules.