Agile controller synchronization not valid responses received in time

Publication Date:  2018-05-29 Views:  179 Downloads:  0
Issue Description

Customer have install the SM+SC in his live network, While configuring server via Init-Server Config Tool customer gets an error "Synchronization not valid responses received in time!"

Customer is using Windows server; Agile Controller version is V100R002C10SPC400

SM+SC  :ip 10.100.240.202

SC-2    :ip 10.100.240.204

Error as bellow:



Alarm Information

N/A

Handling Process

From server SC-2 to pinging SM, it can be success.

In the Init-Server Config Tool we TestConnect the SM, it can be success.

Click next it give error”Synchronization not valid responses received in time!

Check and compare the time between SM and SC, the time is same.

Check the SM and SC window time Service, we found the SM window time Service not running.


Running window time service in SM server. It can working normal with no error.



Root Cause

Window time service not running in SM server cause this error.

Solution

Running window time service in SM server

Suggestions

1 Run the ping SC IP Address command on the SM server to check the network connection between the SM and SC.

2 Check the SM process in SM server

3 Check the date time and time service.

END