Transmission-alarm Configuration Cannot Be Deleted from the POS Interface on the NE5000E

Publication Date:  2013-09-02 Views:  20 Downloads:  0
Issue Description
The transmission-alarm configuration cannot be deleted from the POS interface on the NE5000E.
interface Pos4/1/0                                                              
 link-protocol hdlc                                                             
 undo shutdown                                                                  
 transmission-alarm down lais 

When the transmission-alarm down lais configuration is deleted on POS4/1/0, the following information is displayed:
interface Pos4/1/0                                                              
 link-protocol hdlc                                                             
 undo shutdown                                                                  
 undo transmission-alarm down lais lof los lrdi oof pais prdi sdbere sfbere pune
Handling Process
Analyze the problem. The preliminary conclusion is the incorrect configuration.
Root Cause
N/A
Solution
After the verification and test, LAIS, LOF, and LOS traps are enabled on the POS interface of the NE5000E by default. If the undo transmission-alarm down lais command is executed, the default trap configuration on the POS interface is changed. In addition, other traps are not configured on the POS interface. Therefore, the undo transmission-alarm down lais lof los lrdi oof pais prdi sdbere sfbere pune command is displayed, indicating no alarm configuration on the POS interface.
Run the transmission-alarm down lais lof los command to restore the default trap configuration on the POS interface.
Suggestions

This problem also exists on the NE40E/80E.  