FAQ - What Precautions Must Be Exercised in Replacement of SFUs After an ME60-16 Is Upgraded to V600R002C02SPC700

Publication Date:  2013-09-22 Views:  13 Downloads:  0
Issue Description
After an ME60-16 is upgraded from V100R005C02B01B or V100R006C05SPC600 to V600R002C02SPC700, four SFUs must be replaced so that K boards can be supported. How to properly replace the boards without interrupting services?
Handling Process
N/A
Root Cause
N/A
Solution

Exercise the following precautions when replacing the SFUs:

1. Do not replace the SFUs before the upgrade.

2. After the upgrade, replace the SFUs one by one.

3. After the replacement, check the board registration information and run the check version command to check the version updates.
Suggestions
N/A

END