Alarms About Serdes Interfaces Were Printed Because MPU10 Board Was Not Properly Installed on NE40E

Publication Date:  2013-10-08 Views:  80 Downloads:  0
Issue Description

Version: V600R003C05SPC300

Symptom: Many alarms were printed, indicating that communication between serdes interfaces on an SFU13 board and an LPU board failed.

 Alert            12-12-24  12:47:23      LPU1 is failed, SERDES No.1 channel No.1 with SFU13 SERDES No.9 channel
                                                              No.3 interface is lost synchronization

Emergency  12-12-24  12:47:26    Between SFU13 and LPU4, the communication channel of SERDES interface
                                                              input chip0 channel10 Peer SERDES¡¡chip0 channel0 is failed

 Emergency  12-12-24  12:47:26    Between SFU13 and LPU1, the communicat ion channel of SERDES 
                                                              interface input chip0 channel2 Peer SERDES¡¡chip0 channel0 is failed

 Emergency  12-12-24  12:47:21     SlotID10 is inserted, but some of the connecters are not detected
                                                               [BasCode:0x10200,EntCode:0x23000]
Handling Process
None
Root Cause
The MPU10 board in slot 10 was not properly installed.
Solution
Reseat the MPU10 board in slot 10.
Suggestions
After installing a board, check for new alarms and rectify them if any.

END