R2621 Fails to Interconnect with the Switch of Ericson By R2 Signaling of E1VI Module

Publication Date:  2012-07-27 Views:  107 Downloads:  0
Issue Description
R2621 fails to interconnect with the switch of  Ericson by R2 signaling of E1VI module. 
Alarm Information
No.
Handling Process
Change the signaling used by Ericson switch to No. 1 Chinese signaling, and the interconnection is succeeded, and session is normal then. 
Root Cause
By default, the E1VI module of R2621 is configured with No. 1 Chinese signaling when configuring R2 signaling;that what is used by the switch from Ericson at the peer is also R2 signaling. However, R2 is a basic one that could generate multiple variations. Thus, the variation derived from R2 signaling used by Ericson switch disagrees with that sued by R2621, failing the interaction. 

END