FAQ-How to Set the Interval for Collecting Traffic Statistics on an Interface of the S9300

Publication Date:  2012-07-27 Views:  67 Downloads:  0
Issue Description
 Q:
How to set the interval for collecting traffic statistics on an interface? 

 
Alarm Information
 None 

 
Handling Process
 A:
By default, the interval for collecting traffic statistics on an interface of the switch is 300 seconds. You can set a smaller value for the interval in emergency situations to observe the traffic distribution on an interface within a short time. Run the following commands to set the interval for collecting traffic statistics on an interface:
<Quidway> system-view
[Quidway] interface GigabitEthernet 9/0/9
[Quidway-GigabitEthernet9/0/9] set flow-stat interval 30 

 
Root Cause
 None 

 
Suggestions
 The set flow-stat interval x command is also used on the S23&33&53 series. To set the interval for collecting traffic statistics on an interface of an H3C switch, run the flow-interval x command in the interface view. 

 

END