传输鸳鸯线导致E1对接物理up协议down

发布时间:  2014-09-15 浏览次数:  343 下载次数:  5
问题描述
某新建工程,二个区域新增4台AR4680并分别采用2E1链路进行捆绑对接,组网详见附件,在网络调测中发现其中一个捆绑链路中的一条链路物理上已经up,但协议一直是down的。
告警信息
1、捆绑链路中Serial2/0/0:0 接口状态如下:
[SZIN-RT039A-LH02YW-Serial2/0/1:0]dis int  Serial2/0/0:0 
Serial2/0/0:0 current state :UP   
Line protocol current state :DOWN
Description : "To SZIN-RT041A-BT04YW_Serial2/0/1:0" 
The Maximum Transmit Unit is 1500, Hold timer is 10(sec) 
Derived from E1 2/0/0,  Unframed mode,  baudrate is 2048000 bps
Internet protocol processing : disabled
Link layer protocol is PPP, loopback is detected  
LCP closed
Output queue : (Urgent queuing : Size/Length/Discards)  0/50/0
Output queue : (Protocol queuing : Size/Length/Discards) 0/500/0 
Output queue : (FIFO queuing : Size/Length/Discards)  0/75/0
Last clearing of counters: Never
Error packet detect: Initial
    Last 300 seconds input rate 15.53 bytes/sec, 124 bits/sec, 0.73 packets/sec
    Last 300 seconds output rate 15.53 bytes/sec, 124 bits/sec, 0.73 packets/sec
    Input: 653836 packets, 13909734 bytes
           0 broadcasts, 0 multicasts
           4 errors, 0 runts, 4 giants
           0 CRC, 0 align errors, 0 overruns
           0 dribbles, 0 aborts, 0 no buffers 
           0 frame errors
    Output:653842 packets, 13921774 bytes
           0 errors, 0 underruns, 0 collisions
           0 deferred
2、捆绑链路状态如下:
[SZIN-RT039A-LH02YW-Serial2/0/1:0]dis ppp mp 
Template is Virtual-Template0
max-bind: 16, min-fragment: 128
 Bundle 3ef9250c03bc, 1 members, slot 0, Master link is Virtual-Template0:0
 Peer's endPoint descriptor: 3ef9250c03bc
 Bundle Up Time:        2011/04/27  17:24:33:232
  0 lost fragments, 651 reordered, 0 unassigned, 0 interleaved, 
 sequence 650/902 rcvd/sent, rxload 1%, txload 1%
 The member channels bundled are:
      Serial2/0/1:0     Up-Time:2011/04/27  17:24:33:232
inactive member channels: 1 members
      Serial2/0/0:0     (inactive)
处理过程
1、核对配置脚本,二组捆绑配置方法一致,其中一组的端口、协议均没有问题,故排除配置脚本问题。
2、分别在问题链路进行如下自环测试:
首先分别在二个区的本端做自环测试(本端AR4680到本端传输DDF架侧自环),二个区测试结果显示物理up,协议down,正常。
然后分别在本端AR4680到对端的DDF侧进行自环测试,测试结果显示为本端物理up,协议down;对端物理up,协议down;正常情况应该是本端物理up,协议down;对端物理down,协议down才对;故可确定为中间传输问题。
3、协调传输兄弟进行核对,果然中间传输有一处跳到别的新建设备上了;经传输调整后,故障排除。
根因
1、数据配置问题。
2、传输问题。
建议与总结
涉及到中间经过传输的链路对接,一定要先进行自环测试,确保传输物理上没有问题。
自环测试分为二个部分:
1、本端设备到本端DDF侧自环,可验证本端设备到DDF链路是否正常。
2、本端设备到远端DDF侧自环,同时观察对端链路状态;可验证中间传输是否正常。

END