How to Locate A Power Fault?

Publication Date:  2012-07-17 Views:  81 Downloads:  0
Issue Description
Several USG5300 devices configured with dual power supply modules arrive at an office site. After they are installed and powered on, the pow2 indicator of one USG5300 device is off.
Alarm Information
None.
Handling Process

1.          Check the power indicator on the rear of the device. The indicator of the power supply module is off.

2.          Power on the suspected faulty power supply module. If the module cannot be powered on normally, it is faulty.

Root Cause
One power supply module is damaged.
Suggestions
In addition to checking the pwr indicator and the power indicator on the rear, you can power on the suspected faulty power supply module to check whether it can start up normally.