USG9100启动完成后SPU板无法注册成功

发布时间:  2012-07-18 浏览次数:  61 下载次数:  0
问题描述

USG9100启动完成后,检查单板注册情况,发现SPU板无正常注册,并且出现CRC错误的告警信息,如下所示:

<USG9100>dis  device

Secoway USG9100's Device status:

Slot #    Type    Online    Register      Status      Primary  

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1         MSU     Present   NA            Normal      Master   

3         SPUA    Present   Unregistered  Abnormal    NA       

7         PWR     Present   NA            Normal      NA       

8         PWR     Present   NA            Normal      NA       

9         FAN     Present   Registered    Normal      NA       

10        FAN     Present   Registered    Normal      NA       

11        SMM     Present   NA            Normal      Master   

 

MSU receive request msg from slot 3. 2011/8/31 14:37:38

Loading package flash1:/usg9100v100r001c00spc600.cc from raw.

 ERROR: AllCRC Checksum Is Incorrect!

Package check fail.

告警信息
处理过程

重启设备,重新进行版本加载,完成SPU板的正常注册。

根因

查看相关手册及故障信息内容,确定问题是由于SPU板加载的文件存在问题,CRC校验失败,导致SPU板无法正常注册。

建议与总结
由于MPU的nand-flash有一定的损坏块的概率,这个是由器件所决定的,所以设计了一个保护的机制,设定了一个备份区,如果主区损坏,再次重启时,会通过备份区修复主区的文件。

END