Issue Description

Product and version information:

  • S5500T V100R001 V100R002
  • S5600T V100R001 V100R002
  • S5800T V100R001 V100R002
  • S6800T V100R001 V100R002
  • Host operating system: Microsoft Windows Server 2008 Enterprise X64 Edition SP2
  • Cluster software: Microsoft WSFC
  • Cluster software version: operating system native cluster software version 6.0

The storage array was directly connected to the host through two redundant paths. Read/Write operations were performed on the LUN mapped to the host. After the LUN mappings were changed, we found out by scanning for LUNs on the host that LUN 0 was offline. We ran the online command on this LUN and were prompted with a message stating Error V-76-58659-54 Failed to online disk.

Alarm Information
None
Handling Process
Delete the LUN mapping that cannot become online and then delete the LUN. Map another LUN to the host and ensure that the LUN mapping becomes online.
Root Cause
Verify that the error information is Error V-76-58659-54 Failed to online disk.
Suggestions

Delete the LUN mapping that cannot become online and then delete the LUN. Map another LUN to the host again and ensure that the LUN mapping becomes online.

  • SF is an aggregate of the storage management software provided by Huawei Symantec to offer a complete solution of managing heterogeneous storage arrays online. SF includes VXVM and VXFS.
  • Error V-76-58659-54 Failed to online disk is a general error that cannot be diagnosed.