Failure to Synchronize Data and the Associated Error Message Displayed

Publication Date:  2012-07-23 Views:  95 Downloads:  0
Issue Description
Data synchronization fails and the system displays the associated error message.
Alarm Information
None
Handling Process

Step 1     Ensure that the privilege level and password on the VSM are the same as those on the NE.

1.         Run the following command to view configurations on the NE:display current-configuration

2.         On the VSM, set the same privilege level and password as those on the NE. In the NE Explorer of the NE, choose NE Channel Management > VTY Service and set the related parameters.

Step 2     Data synchronization may fail if the structure of the live network is complex. Select the feature again and then synchronize data separately.

Root Cause

The privilege level and password on the VSM are different from those on an NE.

The network structure is complex and synchronizing other services results in the synchronization failure.

Suggestions
None

END