Title: We can’t find real-time alarm when changing the way of response on NIP console.

Publication Date:  2012-09-10 Views:  124 Downloads:  0
Issue Description
We can’t find real-time alarm when changing the way of response on NIP console.
Alarm Information
None
Handling Process
Real-time alarm is a basic response way of intrusion-detection system, when we need set other response way, the following measure are essential:
1 Don’t change the default detection policy but add a new policy which is the needed response way (recommend).
2 Change the response way of default policy to both contain regular log and other needed way.
Root Cause
There is a default policy on system testing policy, the response way of this policy is regular log. If we change the response way of default policy to the way not contain regular log, there will no real-time alarm information sent to console.
Suggestions
None