SRG3230的E1与NE40E的E1对接出现不通现象

发布时间:  2013-06-28 浏览次数:  281 下载次数:  0
问题描述
版本:V100R002C02SPC500
SRG3230与NE40E使用E1口对接,中间有传输设备,配置IP地址后PING不通。

告警信息
设备上打印提示信息:
2011-09-06 09:28:31 LX-X-SRG3250-R1 %%01PHY/4/PHY(l): E1 9/0/0: The configuration of the CE1 interface card is inconsistent with that of the peer interface card. Please check the configuration
处理过程
调整中间设备的时隙,保持与上下行设备一致
根因
本段配置脚本:
interface Mp-group1
description TO-[SZX-B-NE40E-X8-R1][Mp-group2/1/16][1G]
ip address 172.1.3.62 255.255.255.252
isis enable 100
isis cost 500 level-2                   
isis authentication-mode md5 MQ5&H1N;U&D&P-UR!Y*%'1!!
qos reserved-bandwidth pct 100
mpls
mpls ldp
qos apply policy cbq outbound
#
interface Serial9/0/0:0
link-protocol ppp
ppp mp Mp-group 1
#
interface Serial9/0/1:0
link-protocol ppp
ppp mp Mp-group 1

对端配置脚本:
interface Mp-group2/1/16
description TO-[LX-X-SRG3250-R1][mp-group1][4M]
ip address 172.1.3.61 255.255.255.252
isis enable 100
isis authentication-mode md5 MQ5&H1N;U&D&P-UR!Y*%'1!!
isis cost 500 level-2
isis timer hello 3
isis timer holding-multiplier 4
mpls
mpls ldp                                
port-queue be wfq shaping cir percentage 20 pir percentage 21
port-queue af1 wfq shaping cir percentage 30 pir percentage 31
port-queue af2 wfq shaping cir percentage 50 pir percentage 51
port-queue ef pq shaping pir 2048
#
interface Serial2/1/0/31:0
link-protocol ppp
ppp mp Mp-group 2/1/16
crc 16
#
interface Serial2/1/0/32:0
link-protocol ppp
ppp mp Mp-group 2/1/16
crc 16

中间传输设备问题,设备的时隙配置不一致引起
建议与总结

END