S5700 switch could not find the 10GE interface

Publication Date:  2014-09-12 Views:  641 Downloads:  0
Issue Description
S5700 switch could not find the 10GE interface after installation
when i display interface brief
I didn't see this interfaces
Alarm Information
Null

Handling Process
This mean you must install ETPB first for ES510X4S


Root Cause
After searching your output, I didn’t found this ETPB card

==============================================
=============== display device ================
==============================================
S5700-52C-PWR-EI's Device status:
Slot  Sub Type         Online    Power      Register       Status     Role
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0     -   5752C-PWR    Present   PowerOn    Registered     Normal     Master
      1   ES510X4S     Present   PowerOn    Registered     Normal     NA  
      2   TPC          Present   PowerOn    Registered     Normal     NA  
      3   FAN          Present   PowerOn    Registered     Normal     NA  
      4   POWER        Present   PowerOn    Registered     Normal     NA  
      5   POWER        Present   PowerOff   Registered     Abnormal   NA  


Kindly be notice that:
• An ES5D000X4S01 front card must be used with an ES5D00ETPB00 extended rear card; otherwise, exceptions may occur on the ES5D000X4S01 front card.
• An ES5D000X4S01 front card must be used with an ES5D00ETPB00 card whose PCB version is VC
Suggestions
Null

END