S9700与友商设备BFD静态路由绑定

发布时间:  2014-09-15 浏览次数:  537 下载次数:  0
问题描述
s9700和友商设备对接:
其中9700侧设备网段:10.181.56.0 24 ,H3C侧设备网段:10.181.40.0 24
两端分别设置静态路由到对方
s9700配置:本端互联地址为:10.181.70.1/30 10.181.81.1/30
ip route-static 10.181.40.0 255.255.255.0 10.181.70.2
ip route-static 10.181.40.0 255.255.255.0 10.181.81.2 preference 100
H3C设备配置:本端互联地址:10.181.70.2/30 10.181.81.2/30
ip route-static 10.181.56.0 255.255.255.0 vlan-interface 70 10.181.70.1
ip route-static 10.181.56.0 255.255.255.0 vlan-interface 70 10.181.81.1 preference 100
当主链路断了,业务不通。

告警信息
主链路断路,两端设备无法ping通
处理过程
在s9706上配置:
bfd bb bind peer-ip 10.181.70.1 interface Vlanif70 source-ip 10.181.70.2 auto
min-tx-interval 500
min-rx-interval 500
commit
#
ip route-static 10.181.40.0 255.255.255.0 10.181.70.2 track bfd-session bb
ip route-static 10.181.40.0 255.255.255.0 10.181.81.2 preference 100
H3C设备配置:
interface vlan-interface 70
ip add 10.181.70.2 24
bfd min-tx-interval 500
bfd min-rx-interval 500
ip route-static 10.181.56.0 255.255.255.0 vlan-interface 70 10.181.70.1 bfd control-packet
ip route-static 10.181.56.0 255.255.255.0 10.181.81.1 preference 100
根因
由于静态路由不会感知路由故障,因此主路由故障,即便优先级低的路由也不会生效,需要BFD会话检测主链路,主路由绑定BFD会话,借助BFD会话检测故障发生路由切换
建议与总结
当配置双静态路由时,当主链路断路后,无法感知到路由故障,需要配置BFD检测故障切换路由。

END