FAQ-The backup time is less than three days or battery disconnection protection is triggered.

Publication Date:  2014-10-30 Views:  395 Downloads:  0
Issue Description
The backup time is less than three days or battery disconnection protection is triggered.
Solution
Possible Cause:PV modules are damaged, or storage batteries are faulty, or PV modules are dusty.

Measure:

 PV modules are dusty: Clean the PV modules.

 PV modules are damaged: Replace the PV modules.

 Storage batteries are faulty: Replace the batteries.

END