S127堆叠后通过堆叠系统无法登陆备框的NGFW Module

发布时间:  2014-11-07 浏览次数:  140 下载次数:  0
问题描述
两台S127堆叠后,通过堆叠系统无法登陆备框的NGFW Module。
处理过程
情况1:堆叠主无法直接登陆备框的NGFW(connect后的槽位号只有主框堆叠ID)
<HUAWEI>connect slot ?
  <1>  Chassis ID

情况2:通过local-telnet slave切换到备框后登陆(有报错)
<HUAWEI>local-telnet slave
Info: Succeeded in entering local-telnet, and you can return to the user view with Ctrl + K.
<HUAWEI>connect slot 2/3
Error: There is no response because the system is in the slave state.

解决方法:
S127登陆备框的NFGW Module需先通过堆叠主切换到堆叠备,在诊断视图下开启命令cli enable-config  再connet连接即可。
<HUAWEI>local-telnet slave
Info: Succeeded in entering local-telnet, and you can return to the user view with Ctrl + K.
<12708_127>sy                                                                                                                      
Enter system view, return user view with Ctrl+Z.                                                                                   
[12708_127]dia                                                                                                                     
Enter diagnosis view, return user view with Ctrl+Z.                                                                                
Info: The diagnosis view is used to debug system hardware and software. Misuse of certain commands in this view may affect system pe
rformance. Therefore, use these commands with the guidance of Huawei engineers.
[12708_127-diagnose]cli enable-config                                                                                                   
Warning: After a permissions to execute command lines is obtained, the misuse of some commands may deteriorate system performance. T
herefore, use these commands with assistance from Huawei engineers. Continue? [Y/N]:y                                              
[12708_127-diagnose]q                                                                                                              
[12708_127]q                                                                                                                       
<12708_127>con                                                                                                                     
<12708_127>connect slot 2/3                                                                                                        
******************************************************                                                                             
*              Slot  3 output to mainboard           *                                                                             
******************************************************                                                                             
Press Ctrl+D to quit  

根因
堆叠备的诊断视图下未开启cli enable-config导致无法登陆备框NFGW.
解决方案
从堆叠主登陆到堆叠备,并在其诊断视图下开启cli enable-config,再connect slot X/X。

END