FAQ-S9300 interface command “trap-threshold” configuration Notes

Publication Date:  2014-12-30 Views:  25312 Downloads:  1
Issue Description
Q: S9300 interface command “trap-threshold” configuration Notes
Solution
A: After S9300 interface should also need to open the following configuration snmp trap function can be achieved only after the corresponding module interface when traffic exceeds the threshold set print warning, as follows:

[S9303]interface  GigabitEthernet 1/0/0
[S9303-GigabitEthernet1/0/0] trap-threshold input-rate 70
[S9303-GigabitEthernet1/0/0] trap-threshold output-rate 70
[S9303]snmp-agent trap enable feature-name ifnet trap-name hwifmonitorinputraterising
[S9303]snmp-agent trap enable feature-name ifnet trap-name hwifmonitorinputrateresume
[S9303]snmp-agent trap enable feature-name ifnet trap-name hwifmonitoroutputraterising
[S9303]snmp-agent trap enable feature-name ifnet trap-name hwifmonitoroutputrateresume

If you do not turn on the above features, the trapbuffer equipment which is not recorded in the relevant alarm information, and the other should be noted that after just open snmp trap enable the above function is subsequently opened, do not be individually configured.