An Interface on the SA Card Cannot Go Up

Publication Date:  2015-04-01 Views:  303 Downloads:  0
Issue Description
The physical interface and protocol status of the SA card cannot go Up.

Serial1/0/0 current state : DOWN
Line protocol current state : DOWN
Description:HUAWEI, AR Series, Serial1/0/0 Interface
Route Port,The Maximum Transmit Unit is 1500, Hold timer is 10(sec)
Internet Address is 172.20.18.22/30
Link layer protocol is nonstandard HDLC
Last physical up time   : 2012-08-09 16:04:29
Last physical down time : 2012-08-09 16:04:29
Current system time: 2012-08-09 16:32:47
Physical layer is synchronous, Virtualbaudrate is 64000 bps
Interface is DTE, Cable type is V24, Clock mode is TC
Last 300 seconds input rate 0 bytes/sec 0 bits/sec 0 packets/sec
Last 300 seconds output rate 0 bytes/sec 0 bits/sec 0 packets/sec
Handling Process
1.  When the remote device does not receive signals, run the following command to configure the device to invert clock signals sent by a synchronous serial interface:

[Huawei-Serial1/0/0]invert transmit-clock

2.  When the local device does not receive signals, run the following command to configure the device to invert clock signals received by a synchronous serial interface:

[Huawei-Serial1/0/0]invert receive-clock

NOTE:
Clock signals transmitted by a synchronous serial interface can be inverted only when the AR3200 functions as a DTE.
Performing the preceding operations can solve most problems of the interface on the SA card not in Up state.

Root Cause
The clock phases of two devices connected by the interface of the SA card are inconsistent.