数通产品S9300 静态路由与NQA联动失败故障

发布时间:  2015-04-17 浏览次数:  373 下载次数:  0
问题描述

版本信息:S9300 V200R003C00SPC500

问题描述:9300配置了静态路由与NQA联动,关闭NQA测试实例绑定的目的IP下一跳的接口(唯一的下一跳),静态路由并没有被删除。

处理过程

1.查看配置:

ip route-static 10.48.36.0 255.255.255.0 10.51.32.1 track nqa llqxj llqxj

#

nqa test-instance llqxj llqxj

 test-type icmp

 destination-address ipv4 10.48.36.15

 frequency 3

 start now

#

NQA实例已经配置,且静态路由已与该NQA实例绑定

2.查看NQA检测实例状态

[Quidway-nqa-llqxj-llqxj]di nqa re

 

 NQA entry(llqxj, llqxj) :testflag is active ,testtype is icmp 

  1 . Test 631 result   The test is finished

   Send operation times: 1              Receive response times: 1          

   Completion:no result                 RTD OverThresholds number: 0       

   Attempts number:1                    Drop operation number:0            

   Disconnect operation number:0        Operation timeout number:0         

   System busy operation number:0       Connection fail number:0           

   Operation sequence errors number:0   RTT Status errors number:0         

   Destination ip address:10.48.36.15                                    

   Min/Max/Average Completion Time: 25/25/25                             

   Sum/Square-Sum  Completion Time: 25/625                               

   Last Good Probe Time: 2015-02-09 16:39:40.1                           

   Lost packet ratio: 0 %                                                

  2 . Test 632 result   The test is finished

   Send operation times: 1              Receive response times: 1          

   Completion:no result                 RTD OverThresholds number: 0       

   Attempts number:1                    Drop operation number:0            

   Disconnect operation number:0        Operation timeout number:0         

   System busy operation number:0       Connection fail number:0           

   Operation sequence errors number:0   RTT Status errors number:0         

   Destination ip address:10.48.36.15                                    

   Min/Max/Average Completion Time: 17/17/17                             

   Sum/Square-Sum  Completion Time: 17/289                               

   Last Good Probe Time: 2015-02-09 16:39:43.1                           

   Lost packet ratio: 0 

发现完成每次检测的状态都为 no result,表示该次测试没有成功产生结果。测试结果应该是sucess或者fail,无法产生结果很可能是NQA测试实例的参数配置问题。

3.NQA实例测试的几个关键参数

1)timeout 表示一次探测的超时时间,以ICMP测试为例,在超时时间内未收到对端的回应,则认为本次探测失败。默认为3S

2)probe-count 表示一次NQA实例中探测的次数,默认为3次

3)fail-percent 表示一次测试失败百分比,失败的探测次数占总探测次数的比例超过该值则认为本次NQA测试失败。默认为100%

4)frequency 表示自动执行NQA实例的间隔时间。默认没有开启自动执行。

回到本问题,NQA实例下只配置了frequency为3S,其他参数均为默认值。不难看出NQA自动执行的间隔小于每次测试的总时长:timeout×probe-count,所以每次测试都无法成功产生结果。

根因

NQA实例参数设置不合理。

解决方案

配置NQA实例应遵循以下原则

Timeout×probe-count<frequency

NQA参数修改后,能正确产生测试结果,静态路由联动也能成功实现。

END